REGIONAL FEASIBILITY STUDY ON DISTRICT SEWAGE HEAT SUPPLY WITH GIS
-
- ICHINOSE Toshiaki
- JAPAN SOCIETY OF CIVIL ENGINEERS
-
- KAWAHARA Hiromitsu
- JAPAN SOCIETY OF CIVIL ENGINEERS
Bibliographic Information
- Other Title
-
- GISによる下水熱源地域熱供給事業の地域別適性評価
- GIS ニ ヨル ゲスイ ネツゲン チイキ ネツ キョウキュウ ジギョウ ノ チイキ ベツ テキセイ ヒョウカ
Search this article
Abstract
Spatial conformity between heat demand and waste heat supply was analyzed in Tokyo with GIS. For the regional feasibility study on the district sewage heat supply, the relationships between demand and supply, and the probability of heat use were classified. In case that heat pumps were settled at 3 points along an each series of sewer line, the percentage of total usable heat and the usable heat per a heat pump were analyzed as indicators representing the characteristics of the relationships between demand and supply in each series of sewer line. The result showed a high feasibility in Shibaura Sewage Treatment District in the central business district of Tokyo.
Journal
-
- Doboku Gakkai Ronbunshu
-
Doboku Gakkai Ronbunshu 2000 (643), 29-36, 2000-02-22
Japan Society of Civil Engineers