APPLICATION OF INTEGRITY TESTS FOR QUALITY CONTROL OF CAST-IN-SITU PILES

Bibliographic Information

Other Title
  • インティグリティ試験による場所打ち杭の品質管理法
  • インティグリティ シケン ニ ヨル バショウチ クイ ノ ヒンシツ カンリホウ

Search this article

Description

In the quality control for cast-in-situ piles, it is hard to estimate the condition of piles after the concrete placing. Therefore, the tape measure is used generally for depth measurement of the excavated hole just after drilling. However, it is feared that the pile shape is different from the design one by the influence of ground water. Far the purpose of researching the applicability of the integrity test that is a nondestructive method, we carried out field tests in 26 sites of nationwide. The following results are obtained from the tests: (1) Integrity tests are useful for the estimation of the pile length, however, errors (about 3%) are included in test results, (2) If the stiff middle layer exists, estimation errors will increase, (3) Statnamic testis fully practical for relatively short piles.

Journal

Citations (4)*help

See more

References(15)*help

See more

Details 詳細情報について

Report a problem

Back to top