Measurement for the Interocciusal Ditances at Maximum Intercuspation using a bundle of Registration Strips

DOI

Bibliographic Information

Other Title
  • レジストレーション・ストリップスを用いた咬頭嵌合位における咬合面間距離の計測

Search this article

Abstract

The interocclusal distances of the upper and lower study models mounted on a semi-adjustable articulator are in maximum Intercuspation were measured, using a bundle of registration strips. The average interocclusal distance was 0.10±0.10mm for the molars. Providing the diameter of man's hair is about 30 microns, then three hairs will pass through the clearance between upper and lower teeth in maximum intercuspation.

Journal

Details 詳細情報について

Report a problem

Back to top