書誌事項
- タイトル別名
-
- Removal of Ambient Air Pollution by Activated Carbon Fiber (ACF) installed in flow-through fence: Numerical Evaluation of its Performance in Realistic 3D Space
- タイキ キョウカイソウ ナイ ノ ランリュウ コウゾウ ノ カイメイ ニ カンスル ジッケンテキ ケンキュウ : カンキョウ リュウタイ フウドウ ノ セッチ ト タイキ キョウカイソウ ノ サイゲン
この論文をさがす
抄録
Numerical investigation of NOx removal by activated carbon fiber (ACF) set within porous fences was performed in a realistic 3D situation. The fence units were placed along road with a fixed interval so that they cover the road side by about 50%; that is one possible way to reduce use of now expensive ACF. Then, how much the ACF fences can decrease ambient NOx concentrations was evaluated. Obtained results showed:(1) NOx concentration, for example, at 10m downstream from the road can be reduced as much as 20% even by the ACF fences which cover the road partially.(2) this removal efficiency without excess energy consumption should be very promising as a tool for sustainable preservation of urban environment.
収録刊行物
-
- 地球環境シンポジウム講演論文集
-
地球環境シンポジウム講演論文集 14 53-58, 2006
公益社団法人 土木学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001205400859520
-
- NII論文ID
- 130004128965
-
- NII書誌ID
- AA12454135
-
- ISSN
- 21852375
- 18848419
-
- NDL書誌ID
- 024681553
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可