シールドマシン地中接合用分割ドッキングフード部の止水対策
書誌事項
- タイトル別名
-
- WATERTIGHT MEASURES AT DIRECT UNDERGROUND DOCKING POINT BY TWO SLURRY SHIELD MACHINES
抄録
In Narita sand layer, direct underground docking of two shield machines was performed using partitive docking hoods. Since the ground is liquescent, chemical grouting was necessary as a auxilliary watertight measure to prevent inflow of sand and grand water at the openings between machine and partitive docking hoods. Newly developed evaluation method using the Elastic Finite Element Analysis was applied, in order to estimate the minimum chemical grouting area. Thereafter, grouting and following direct docking was executed, though inflow of grand water was observed. Thus, the performance of this evaluation method as well as the critical watertight devices previously equipped with the docking shield machines should be thoroughly assessed, as indicated in this paper.
収録刊行物
-
- トンネル工学研究発表会論文・報告集
-
トンネル工学研究発表会論文・報告集 4 275-280, 1994