熱風爐の構造とその熱能率に就て

書誌事項

タイトル別名
  • ON THE HEAT EFFICIENCIES OF HOT STOVES.

この論文をさがす

説明

Temperature distributions in Three-pass stove and two Cowper stoves of different design in details at Yawata Steel Works, firing, gases and airs supplied to them were measured. From these results, heat efficiency of each hot stove was calculated, and firing gases were compared with the hot airs used to the blast furnaces. Moreover, actual amount of hot airs given, to the furnaces and produced gases recorded by each gas-meter, real amounts of them measured by the method of Pitot-tube and true values of them caleulated from ores and others are examined.

収録刊行物

  • Tetsu-to-Hagane

    Tetsu-to-Hagane 22 (3), 165-180, 1936

    一般社団法人 日本鉄鋼協会

参考文献 (9)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘