- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Investigations on the Track of the Stimulus Using a Training Software for Performing Goldmann Perimetry
-
- Kobayashi Akiko
- Department of Ophthalmology, Tokyo Medical University Hospital
-
- Ubukata Hokuto
- Department of Orthoptics and Visual Sciences, Faculty of Medical Technology, Niigata University of Health and Welfare
-
- Maeda Fumiatsu
- Department of Orthoptics and Visual Sciences, Faculty of Medical Technology, Niigata University of Health and Welfare
-
- Kawano Jun-ichi
- Department of Orthoptics and Visual Sciences, School of Health Science, Kyushu University of Health and Welfare
-
- Kani Kazutaka
- Department of Orthoptics and Visual Sciences, School of Health Science, Kyushu University of Health and Welfare
Bibliographic Information
- Other Title
-
- ゴールドマン視野計練習用シミュレーションシステムによる視標軌跡の検討
Search this article
Description
<p>Purpose: We developed a training software for performing Goldmann perimetry (GP) that records the track of the stimulus. We analyzed how the visual field (VF) was tested with this software and evaluated our technical training program for performing GP.</p><p>Methods: Using the software, a VF with glaucomatous changes was examined by 6 orthoptic students and 6 orthoptists with clinical experiences for at least 5 years. The movement of the stimulus in the periphery obtained by the students and orthoptists was analyzed and compared.</p><p>Results: The orthoptists could plot more response points than the students, especially in the area with VF defects. The average stimulus speed was about 5°/sec and was 2°/sec right before the response points being connected for both students and orthoptists. The students moved the stimulus at a constant speed while the orthoptists moved the stimulus at a gradually decreasing speed.</p><p>Conclusions: In a VF test, it is important that the examiner has some general assumption about the VF defects to be tested. This training software can help the examiners become more familiar with various VF test results and acquire necessary skills in performing GP.</p>
Journal
-
- Japanese Journal of Visual Science
-
Japanese Journal of Visual Science 39 (1), 5-10, 2018
The Japanese Society of Ophthalmological Optics
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001205513441024
-
- NII Article ID
- 130006743562
-
- ISSN
- 21880522
- 09168273
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- CiNii Articles
- KAKEN
-
- Abstract License Flag
- Disallowed