Reduction of breakdown voltage of an EEFL by use of a 4-electrode drive
-
- Asaka Takashi
- The University of Electro-Communications
-
- Shiga Tomokazu
- The University of Electro-Communications
-
- Igaeashi Kiyoshi
- The University of Electro-Communications
Bibliographic Information
- Other Title
-
- EEFLの4電極駆動による放電開始電圧の低減
Description
Using a 4-electrode drive, a breakdown voltage of an EEFL was reduced. Two sets of electrodes were provided on the EEFL at an interval of 100mm. Each of the sets consisted of a couple of electrodes facing each other. Applied voltages to the facing electrodes had a phase difference of 0-1us. The voltage waveform of one of the electrode sets were inverted from the other. When the phase difference was 100ns, the breakdown voltage was reduced from 830V to 460V, and the maintenance voltage was reduced from 370V to 347V.