A Study on Countermeasures for Wake Galloping in Parallel Cables of Cable-Stayed Bridges
-
- Hata Kensaku
- Honshu-Shikoku Bridge Authority, Engineering Management Division
-
- Kusuhara Shigeki
- Honshu-Shikoku Bridge Authority, Engineering Management Division
-
- Hanai Taku
- Honshu-Shikoku Bridge Authority, Second Operation Bureau, Bridge Maintenance Division
Bibliographic Information
- Other Title
-
- 斜張橋並列ケーブルのウェイクギャロッピング制振対策検討
Abstract
Wake galloping and other vibrations were observed in the cables of the Hitsuishi-jima Bridge and Iwakuro-jima Bridge of the Honshu-Shikoku Bridges, and spacers and connecting wires were installed to control the vibration of the cables. However, the“Sub-Span Vibrationwith” with limited amplitude has been observed since the completion of the bridges, and it seems that this vibration causes the damage in the connecting wires. The application of the trip wires as the countermeasure to this “Sub-Span Vibration” was investigated. Wind tunnel tests with full scale sectional models and field tests were conducted and it was confirmed that the trip wires are effective. In this report, the results of the wind tunnel tests and field tests are reported.
Journal
-
- PROCEEDINGS OF NATIONAL SYMPOSIUM ON WIND ENGINEERING
-
PROCEEDINGS OF NATIONAL SYMPOSIUM ON WIND ENGINEERING 18 (0), 000009-000009, 2005
Japan Association for Wind Engineering
- Tweet
Details 詳細情報について
-
- CRID
- 1390001205593230720
-
- NII Article ID
- 130004644218
-
- Data Source
-
- JaLC
- CiNii Articles
-
- Abstract License Flag
- Disallowed