This paper describes the study on the appropriate test method of the dry density for the shielding concrete. A series of experiments was conducted based on the Latin square method considering cement type and test condition variability. The following conclusions can be drawn.<br>1. The drying convergence time of a concrete specimen depends on the pre-curing period, the shape of the specimen and the drying temperature. The longer pre-curing period, larger specimen size and lower drying temperature make the drying convergence time longer.<br>2. Although there are two judgment criteria for oven-dry condition of the concrete specimen and these two criteria influence the drying convergence time, these two criteria do not influence the dry density of the concrete specimen.