遮へいコンクリートの乾燥単位容積質量試験方法に関する実験的研究

書誌事項

タイトル別名
  • EXPERIMENTAL STUDY ON THE TEST METHOD OF THE DRY DENSITY FOR THE SHIELD CONCRETE
  • シャヘイ コンクリート ノ カンソウ タンイ ヨウセキ シツリョウ シケン ホウホウ ニ カンスル ジッケンテキ ケンキュウ シケン ジョウケン ノ ケントウ
  • Examination of test condition variability
  • 試験条件の検討

この論文をさがす

抄録

This paper describes the study on the appropriate test method of the dry density for the shielding concrete. A series of experiments was conducted based on the Latin square method considering cement type and test condition variability. The following conclusions can be drawn.<br>1. The drying convergence time of a concrete specimen depends on the pre-curing period, the shape of the specimen and the drying temperature. The longer pre-curing period, larger specimen size and lower drying temperature make the drying convergence time longer.<br>2. Although there are two judgment criteria for oven-dry condition of the concrete specimen and these two criteria influence the drying convergence time, these two criteria do not influence the dry density of the concrete specimen.

収録刊行物

詳細情報 詳細情報について

問題の指摘

ページトップへ