書誌事項
- タイトル別名
-
- LATERAL STRUCTURAL PERFORMANCE OF NARROW SIZE CROSS LAMINATED TIMBER CONNECTED WITH TENSILE BOLTS
- コハバ パネル オ ヒキ ボルト セツゴウ シタ CLTヘキ ノ スイヘイリョク ニ タイスル キョドウ
この論文をさがす
抄録
Shear wall tests of single CLT wall of which size is 1x3m were conducted to evaluate the shear performance and 4m width shear wall with opening tests consisting of double 1x3m of CLT panels and hanging panels were also conducted. Tensile bolts were used as connection between the shear wall and foundation, shear wall and hanging wall, and top-bottom of shear walls. Simple tensile tests for every bolt joint, compression, shear and bending tests for CLT panel were conducted to calculate the load-displacement relationship and to derive structural design procedure of the shear wall. As results of these static loading tests, the following conclusions are drawn;<br> 1. Each CLT panel remained elastic and shear deformation of CLT panel is less than the connections deformation. This highlighted seismic performance of CLT construction is controlled by the design and detailing of the connections.<br> 2. Equations to calculate load-displacement relationship of CLT shear walls are computed from the equilibrium of internal and external forces. The equations are validated with the experimental results.
収録刊行物
-
- 日本建築学会構造系論文集
-
日本建築学会構造系論文集 81 (721), 585-593, 2016
日本建築学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001205604557184
-
- NII論文ID
- 200000407759
- 130005140756
-
- NII書誌ID
- AN10438559
-
- ISSN
- 18818153
- 13404202
-
- NDL書誌ID
- 027185926
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
- KAKEN
-
- 抄録ライセンスフラグ
- 使用不可