Wind-induced vibration and rear axial flow of indented stay cables
-
- Katsuchi Hiroshi
- Yokohama National University
-
- Yamada Hitoshi
- Yokohama National University
-
- Hosokawa Genki
- Yokohama National University
Bibliographic Information
- Other Title
-
- インデント斜ケーブルの空力振動と軸方向流特性
Abstract
Characteristics of dry galloping of a stay cable with the indented surface treatment were experimentally investigated. Wind-induced response, surface pressures and axial flow speed were measured in a wind tunnel. It was found that dry galloping occurred in the critical Reynolds region when Karman vortices were suppressed by strong axial flow.