STUDY ON THE EVALUATION OF EARTHQUAKE RESISTANT CAPACITY OF TRADITIONAL TIMBER HOUSES IN CONSIDERATION OF THE FLOOR STIFFNESS AND GRID LINES OF BEARING WALLS

  • YAMADA Koji
    Dept. of Architecture, Toyota National College of Technology

Bibliographic Information

Other Title
  • 床剛性と耐力壁線を考慮した在来軸組木造構法住宅の耐震性能評価に関する研究
  • ユカ ゴウセイ ト タイリョクヘキセン オ コウリョ シタ ザイライジクグミ モクゾウコウホウ ジュウタク ノ タイシン セイノウ ヒョウカ ニ カンスル ケンキュウ

Search this article

Abstract

The evaluation of earthquake resistant capacity of traditional timber houses in consideration of the floor stiffness and grid lines of bearing walls is discussed. The result may be summarized as follows: The ultimate horizontal resistant force with hard stiffness floor is estimated from the one with soft stiffness floor. The minimum value of partial wall-length ratios of the resisting wall is independent of the wall-length ratio of the resisting wall. The resistant force calculated with the minimum value of partial wall-length ratios of the resisting wall has less error than the one calculated with the wall-length ratio of the resisting wall in comparison with the ultimate horizontal resistant force.