Cell parameter measurements of vertically aligned liquid crystal cells

  • Sato Kazuma
    Faculity of Engineering and Resource Science,Akita University
  • Kawamura Marenori
    Faculity of Engineering and Resource Science,Akita University
  • Sato Susumu
    Faculity of Engineering and Resource Science,Akita University

Bibliographic Information

Other Title
  • 垂直配向液晶セルにおけるセルパラメータの測定

Description

We propose a two-dimensional (2D) measurement method for determining cell parameters such as a cell gap and pretilt angle in a vertical alignment liquid crystal (VA LC) cell. The 2D cell parameter distributions can be obtained by measuring Stokes parameters of the LC cell as changing oblique angle of the incident light upon the LC cell.