11303 内航船舶用排熱回収システムにおける排気管流路の圧力損失(エンジン・システム)

書誌事項

タイトル別名
  • 11303 Pressure Drop of Exhaust Pipe for Marine Heat Recovery System

抄録

In order to keep clean a harbor area, we develop a heat recovery system using a Stirling engine. A heat exchanger of the Stirling engine is located into an exhaust gas pipe of a Diesel engine. The pressure drop, which is caused by the heat exchanger, affects to the performance of the Diesel engine strongly. In this paper, the pressure loss is measured with an experimental engine system, and compared with calculated results of a CFD analysis.

収録刊行物

詳細情報 詳細情報について

問題の指摘