F242 深海水を用いた海洋温度差発電を併用することによるABWR熱効率向上に関する研究(OS9 熱・流動(7))

書誌事項

タイトル別名
  • F242 Study on the thermal efficiency improvement in ABWR by the combined use of OTEC using deep-sea water

抄録

Thermal efficiency is very important in power plant. Improvement in thermal efficiency means that it becomes possible to generate more power at the same amount of heat. In this study, a combination of the nuclear power plant and OTEC (Ocean Thermal Energy Conversion) is proposed. The pressure of the condenser of the nuclear power plant is determined by the temperature of the cooling water. So, there is a method of utilizing the waste water from the OTEC as the cooling water. By doing so, the temperature and pressure of the condenser will be reduced, and thermal efficiency in the nuclear power plant will be improved. On the other hand, by directing the warm waste water from the nuclear power plant to a high temperature heat source of the OTEC, the temperature difference between the high and low heat source is expanded, and thermal efficiency in OTEC is also improved.

収録刊行物

詳細情報 詳細情報について

問題の指摘