-
- YAMAMOTO Yasunori
- Hokkaido University
-
- NARABAYASHI Tadashi
- Hokkaido University
-
- KURA Yuki
- Hokkaido University
-
- CHIBA Go
- Hokkaido University
Bibliographic Information
- Other Title
-
- 非常用復水器を用いた静的冷却系に関する研究
- (1)福島第一発電所1号機の作動状況評価
- (1) Evaluation of the operating condition in Fukushima Daiichi Unit 1
Description
<p>In the Fukushima Daiichi Nuclear Power Plant unit 1, isolation condenser (IC) should play an important role in core cooling during station blackout. To evaluate cooling capability of the IC, two phase flow analyses with the TRAC code and experiments for high pressure conditions were conducted. The analyses for the actual BWR indicated that decay heat could be removed if the IC worked properly at 18:18. However, our results showed that core uncovery occurred at 17:30, which will lead to hydrogen production from the heated core. Further efforts should be made to properly consider the effect of hydrogen accumulation for degradation of core cooling. The experiments simulating IC operation indicated that the natural convection occurred and decay heat could be removed by the IC at high pressure conditions.</p>
Journal
-
- The Proceedings of the National Symposium on Power and Energy Systems
-
The Proceedings of the National Symposium on Power and Energy Systems 2017.22 (0), A223-, 2017
The Japan Society of Mechanical Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390001205886858880
-
- NII Article ID
- 130006282225
-
- ISSN
- 24242950
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed