461 コリオリ質量流量計における測定管の腐食診断 : 励振ゲインを固定することによる測定管のばね定数の評価(設備の監視,OS-11 システムのモニタリングと診断,総合テーマ「伝統を,未来へ!」)
書誌事項
- タイトル別名
-
- 461 Diagnosis of Flow Tube Corrosion in Coriolis Mass Flowmeter : Evaluation of Spring Constant by Fixing Excitation Gains
抄録
This paper proposes a diagnostic method of flow tube corrosion in Coriolis mass flowmeter. In order to diagnose the corrosion, our proposed method calculates the spring constant of the flow tube using two change ratios obtained by fixing excitation gains at a driving coil. The main advantage of this method is that Coriolis mass flowmeter can measure the mass flow rate during diagnosis. Through the experimental investigation using non-corroded flowmeter, it is clarified that our proposed diagnostic method can evaluate the spring constant at any operating points.