電界誘起マイクロバブルのキャビテーションにおける衝撃波発生と収束に関する研究

書誌事項

タイトル別名
  • Fundamental Study on generating and focusing shock wave caused by cavitation of electrically-induced micro bubble

抄録

<p>For the present study, the collateral damage area was evaluated for the electrically induced bubble injector (needle-free injector) which was invented in our laboratory. It was confirmed that the input power is closely related to the depth of the injection area. However, the perforation depth of conventional bubble injector is limited as general use of injector. Therefore for the present study, evaluation and amplification of shock wave which is generated in cavitation phenomena is carried out. Also, the reflector to focusing shockwave is designed and fabricated to amplify the injection performance of bubble injector.</p>