An experimental study on the applicability of the light extinction method to a high density particle cloud.
Bibliographic Information
- Other Title
-
- 高数密度粒子群に対する透過光減衰法の適用性に関する実験的研究
- コウ スウ ミツド リュウシグン ニ タイスル トウカコウ ゲンスイホウ ノ
Search this article
Abstract
The applicability of the light extinction method to a dense spray like diesel sprays was investigated experimentally using a glass bead-water suspension having a similar dimension to that of an ordinary diesel spray. The transmission was measured against particle concentration using the detection angle as a parameter. The results showed that the light extinction principle holds at a high particle concentration which is equivalent to that of diesel sprays, and that the apparent extinction coefficient, which was obtained experimentally, coincides within an accuracy of 5 percent with that theoretically calculated.