定電流ステップ入力に対する電位の過渡応答と腐食速度の関係

書誌事項

タイトル別名
  • Relation Between the Corrosion Rate and the Potential Response to an Applied Current Step
  • テイデンリュウ ステップ ニュウリョク ニ タイスル デンイ ノ カト オウト

この論文をさがす

説明

Relation between the corrosion rate and the shape of the potential response curve to an applied current step has been investigated for mild steel immersed in tap water as well as underground water. It was found that the potential response curve approached a straight line as the corrosion current density decreased, when the corrosion potential was more noble than -0.44V vs. SCE. In this case, it was also found that logarithm of the corrosion current density was proportionalto logarithm of ΔE4E10 in the corrosion current density range from 0.69μA/cm2 to 27.2μA/cm2, where ΔE4 and ΔE10 are overvoltage at 4 seconds and 10 seconds after application of current step. Corrosion current densities determined from ΔE4E10 values by the use of the regression equation agreed within 29% with those determined by the weight loss measurement. The surface state of the electrode was discussed and it was concluded that the electrode was in the active/passive transition region when the above dependence of ΔE4E10 values on the corrosion current densities existed.

収録刊行物

詳細情報 詳細情報について

問題の指摘