Repassivation Method for Determining the Critical Concentration of Chloride Ion for Crevice Corrosion of 13Cr Stainless Steel Healds in Diluted NaCl Solution

  • Nakatsu Michiyo
    Industrial Technology Center of Fukui Prefecture
  • Nomura Kouji
    Industrial Technology Center of Fukui Prefecture
  • Fukaya Yuichi
    Materials Reliability Center, National Institute for Materials Science Present, Research Laboratories, Ishikawajima-Harima Heavy Industries Co., Ltd.
  • Shinohara Tadashi
    Materials Reliability Center, National Institute for Materials Science

Bibliographic Information

Other Title
  • 13Crステンレス鋼製部品ヘルドの腐食すきま再不動態化臨界塩化物イオン濃度測定
  • 13Cr ステンレス コウセイ ブヒン ヘルド ノ フショク スキマ サイ フドウタイカ リンカイ エンカブツ イオン ノウド ソクテイ

Search this article

Abstract

Flat healds (13Cr stainless steel, 340 mml×2 mmw×0.3 mmt) used in a water jet loom (WJL) suffer from crevice corrosion in the tap water. In the present work, a repassivation method for determining the critical concentration of chloride ion, Cl, for the growth of crevice corrosion, CR, CREV, was measured using the metal/metal-crevice of heald in NaCl solutions containing less than 40 mg/L Cl. Optimum conditions of potential and current to grow crevice corrosion in the initiation stage (S1) and the growing stage (S2) before the repassivation stage (S3) were examined. A heald was cut into two pieces and then a metal/metal-crevice was formed by overlapping the two pieces. Crevice corrosion was initiated in the solution containing 500 mg/L Cl by a potentiokinetic method in S1. When crevice corrosion was grown at 200 mV vs. SCE in S2 by a potentiostatic method, corrosion area expanded, and then the specimen with two pieces did not work as a creviced one. Then, crevice corrosion in S2 was grown using a galvanostatic method with a current of 200 μA. Before changing to S3, the potential of specimen was raised up to a potential that was 50 mV lower than the holding potential in S3 by diluting test solution. Increases in current were observed after two times of dilution of the test solution in S3. CR, CREV was determined as the highest Cl concentration in diluted test solutions in which no increase in current was observed. Use of galvanostatic method for growing crevice corrosion was desirable in the repassivation method of determination of the CR, CREV, because the quantity of electricity was controlled easily by time. The determined CR, CREV vs. potential relationship coincided well with the extrapolation line of the reported ER, CREV (repassivation potential for crevice corrosion) vs. Cl concentration relationship in the tap water.

Journal

  • Zairyo-to-Kankyo

    Zairyo-to-Kankyo 56 (7), 309-313, 2007

    Japan Society of Corrosion Engineering

Citations (3)*help

See more

References(11)*help

See more