The rotor-tip flow fields in a low-speed axial-flow fan were experimentally and numerically investigated to clarify the mechanism behind the modal stall inception. The interface between the incoming flow and the reversed tip-leakage flow does not become parallel to the leading edge plane, although backflow from the trailing edge initiates near the stall condition. The reversed tip-leakage flow does not spill from the leading edge at the stall condition. Moreover, the tip-leakage vortex breakdown does not occur near or at the stall condition. A threee-dimensional separation vortex is induced by secondary flow on the suction surface near the stall condition and develops at the stall condition. It is concluded from these results that the rotor-tip flow fields in the modal stall inception differ from those in the spike stall inception and that the three-dimensional separation vortex induced by the secondary flow influences the initiation of the modal disturbance.