A New Method of Measuring Length of Pipe by Means of Sound Signals. Detecting Resonant Frequency of Air Column in Pipe.
Bibliographic Information
- Other Title
-
- 音響信号を利用した管の長さ測定 管内空気柱の共振周波数検出
- オンキョウ シンゴウ オ リヨウシタ カン ノ ナガサ ソクテイ カンナイ ク
Search this article
Abstract
This research paper presents a new method of measuring the length of a pipe by using sound frequency. A sweep signal is radiated from the speaker toward the inside of the pipe. The sound pressure at the resonant frequency of the air column in the pipe indicates the largest value. The length of the pipe to be measured corresponds well to the resonant frequency. The phase. locked loop device is adopted to obtain the stabilities of resonation and frequency. A frequency counter with a reciprocal mode is adopted for higher resolution within a shorter time period because of low frequency.
Journal
-
- TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
-
TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C 57 (539), 2217-2222, 1991
The Japan Society of Mechanical Engineers
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001206294925056
-
- NII Article ID
- 110002379922
-
- NII Book ID
- AN00187463
-
- ISSN
- 18848354
- 03875024
-
- HANDLE
- 10191/5793
-
- NDL BIB ID
- 3726725
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- IRDB
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed