- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Effect of Reconstruction Strategies for the Quantification and Diagnostic Accuracy of <sup>123</sup>I-FP-CIT SPECT
-
- Kameiyama Hiroaki
- Department of Radiological Technology, Kurashiki Central Hospital
-
- Matsutomo Norikazu
- Department of Medical Radiological Technology, Faculty of Health Sciences, Kyorin University
-
- Nagaki Akio
- Department of Radiological Technology, Kurashiki Central Hospital
-
- Yamao Fusae
- Department of Neurology, Kurashiki Central Hospital
Bibliographic Information
- Other Title
-
- <sup>123</sup>I-FP-CIT SPECT における画像再構成方法が定量性と診断能に与える影響
- 臨床技術 ¹²³I-FP-CIT SPECTにおける画像再構成方法が定量性と診断能に与える影響
- リンショウ ギジュツ ¹ ² ³ I-FP-CIT SPECT ニ オケル ガゾウ サイコウセイ ホウホウ ガ テイリョウセイ ト シンダンノウ ニ アタエル エイキョウ
Search this article
Description
<p>Purpose: This study evaluates the effect of reconstruction strategies for the quantification and diagnostic accuracy of 123I-FP-CIT SPECT. Methods: We evaluated the quantification of 123I-FP-CIT SPECT obtained by several combinations of reconstruction using the striatal phantom. The phantom images were reconstructed using FBP and OSEM with/without attenuation correction (AC) and scatter correction (SC). We calculated the specific binding ratio (SBR) using volume of interest (VOI) analysis on each reconstructed images. For the clinical study, 40 patients who underwent 123I-FP-CIT SPECT were selected. We grouped the patients into the normal binding group and decreased binding group according to their clinical diagnosis. The clinical images were reconstructed under the same conditions as the phantom study. The SBRs were calculated, and a receiver operating characteristic (ROC) analysis was performed to evaluate the diagnostic accuracy. Results: The SBRs with AC and SC significantly increased compared with no corrections. In the clinical study, although ROC analysis showed no significant difference in the all combinations of reconstruction, the area under the curve using SC and AC tended to be higher than that obtained by other reconstruction. Conclusions: Quantification of 123I-FP-CIT SPECT was affected by reconstruction strategies. In addition, both the AC and SC improved the diagnostic accuracy of 123I-FP-CIT SPECT. Our results suggest that both the AC and SC are recommended for the improving the quantification and diagnostic accuracy in 123I-FP-CIT SPECT.</p>
Journal
-
- Japanese Journal of Radiological Technology
-
Japanese Journal of Radiological Technology 72 (7), 595-601, 2016
Japanese Society of Radiological Technology
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001206362723712
-
- NII Article ID
- 130005165506
-
- NII Book ID
- AN00197784
-
- ISSN
- 18814883
- 03694305
-
- NDL BIB ID
- 027574661
-
- PubMed
- 27440703
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- PubMed
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed