- TANAKA YOSHIMUNE
- From Radiation Division, Shimadzu Seisakusho Ltd.
Bibliographic Information
- Other Title
-
- 線量計を利用してX線装置を相互較正する方法
- センリョウケイ オ リヨウ シテ Xセン ソウチ オ ソウゴ コウセイ スル ホウホウ
Search this article
Abstract
An X-ray xuality and quantity calibration among more than two X-ray apparatus is indispensable for accomplishment to the standardization of radiographic exposure technic. In order to obtain the same X-ray out put auther recommend following method. On the basis of a kV-chart the standard transmission characteristic of X-ray at a certain X-ray tube current as 100mA is created. After measuring an X-ray transmission curve of the apparatus to be calibrated the same condition these two curves are superimposed and determined how they are differed each other. Error of subject tube voltage is estimated from the deviation on the curve.
Journal
-
- Japanese Journal of Radiological Technology
-
Japanese Journal of Radiological Technology 20 (4), 300-307, 1965