Comparison of Three Thermal Cameras with Canine Hip Area Thermographic Images
-
- VAINIONPÄÄ Mari
- Department of Equine and Small Animal Medicine, Pharmacology and Toxicology, Faculty of Veterinary Medicine, University of Helsinki, Koetilantie 7, Finland
-
- RAEKALLIO Marja
- Department of Equine and Small Animal Medicine, Pharmacology and Toxicology, Faculty of Veterinary Medicine, University of Helsinki, Koetilantie 7, Finland
-
- TUHKALAINEN Elina
- Department of Equine and Small Animal Medicine, Pharmacology and Toxicology, Faculty of Veterinary Medicine, University of Helsinki, Koetilantie 7, Finland
-
- HÄNNINEN Hannele
- Department of Equine and Small Animal Medicine, Pharmacology and Toxicology, Faculty of Veterinary Medicine, University of Helsinki, Koetilantie 7, Finland
-
- ALHOPURO Noora
- Department of Equine and Small Animal Medicine, Pharmacology and Toxicology, Faculty of Veterinary Medicine, University of Helsinki, Koetilantie 7, Finland
-
- SAVOLAINEN Maija
- Department of Equine and Small Animal Medicine, Pharmacology and Toxicology, Faculty of Veterinary Medicine, University of Helsinki, Koetilantie 7, Finland
-
- JUNNILA Jouni
- 4Pharma Ltd, Espoo, Finland
-
- HIELM-BJÖRKMAN Anna
- Department of Equine and Small Animal Medicine, Pharmacology and Toxicology, Faculty of Veterinary Medicine, University of Helsinki, Koetilantie 7, Finland
-
- SNELLMAN Marjatta
- Department of Equine and Small Animal Medicine, Pharmacology and Toxicology, Faculty of Veterinary Medicine, University of Helsinki, Koetilantie 7, Finland
-
- VAINIO Outi
- Department of Equine and Small Animal Medicine, Pharmacology and Toxicology, Faculty of Veterinary Medicine, University of Helsinki, Koetilantie 7, Finland
この論文をさがす
抄録
The objective of this study was to compare the method of thermography by using three different resolution thermal cameras and basic software for thermographic images, separating the two persons taking the thermographic images (thermographers) from the three persons interpreting the thermographic images (interpreters). This was accomplished by studying the repeatability between thermographers and interpreters. Forty-nine client-owned dogs of 26 breeds were enrolled in the study. The thermal cameras used were of different resolutions-80 × 80, 180 × 180 and 320 × 240 pixels. Two trained thermographers took thermographic images of the hip area in all dogs using all three cameras. A total of six thermographic images per dog were taken. The thermographic images were analyzed using appropriate computer software, FLIR QuickReport 2.1. Three trained interpreters independently evaluated the mean temperatures of hip joint areas of the six thermographic images for each dog. The repeatability between thermographers was >0.975 with the two higher-resolution cameras and 0.927 with the lowest resolution camera. The repeatability between interpreters was >0.97 with each camera. Thus, the between-interpreter variation was small. The repeatability between thermographers and interpreters was considered high enough to encourage further studies with thermographic imaging in dogs.
収録刊行物
-
- The Journal of Veterinary Medical Science
-
The Journal of Veterinary Medical Science 74 (12), 1539-1544, 2012
公益社団法人 日本獣医学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001206430058496
-
- NII論文ID
- 130001879715
-
- NII書誌ID
- AA10796138
-
- COI
- 1:STN:280:DC%2BC38jpt1KqtQ%3D%3D
-
- ISSN
- 13477439
- 09167250
-
- NDL書誌ID
- 024190357
-
- PubMed
- 22785576
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- PubMed
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可