フェロモリブデン中のアルミニウムおよび硫黄の定量

書誌事項

タイトル別名
  • Determination of Aluminum and Sulfur in Ferro-Molybdenum
  • フェロ モリブデン チュウ ノ アルミニウム オヨビ イオウ ノ テイリョウ

この論文をさがす

抄録

In determining aluminum and sulfur in ferro-molybdenum, iron and molybdenum were removed by using methyl-isobutyl ketone extraction method. After the removal of iron and molybdenum, aluminum was determined gravimetrically or volumetrically by using oxine, by which 0.1∼1 per cent aluminum in ferro-molybdenum was determined. By using methyl-iso-butyl keton for ether, the danger of explosion caused by organic vapour and the disturbance of molybdenum were avoided. Sulfur was determined gravimetrically as barium sulfate down to 0.005 per cent content of it. The present procedure is superior in its simplicity and in being free of the obstruction by molybdenum trioxide to the usual combustion method for sulfur.

収録刊行物

  • 日本金属学会誌

    日本金属学会誌 24 (6), 363-366, 1960

    公益社団法人 日本金属学会

詳細情報 詳細情報について