Enhancement of Cross-Tension Strength of Resistance Spot-Welded Lap Joints by Laser Heating

  • Kitamura Takanori
    Department of Materials Science and Engineering, Faculty of Engineering, Kyushu Institute of Technology
  • Akiyama Tetsuya
    Department of Materials Science and Engineering, Faculty of Engineering, Kyushu Institute of Technology
  • Asada Masaru
    Department of Materials Science and Engineering, Faculty of Engineering, Kyushu Institute of Technology

Bibliographic Information

Other Title
  • 抵抗スポット溶接重ね継手十字引張強度のレーザ加熱による高強度化
  • テイコウ スポット ヨウセツ カサネ ツギテ ジュウジ ヒッパリ キョウド ノ レーザ カネツ ニ ヨル コウキョウドカ

Search this article

Abstract

  This paper deals with the strengthening of spot-welded lap joints through the formation of a new hardened zone (HAZ). The factors needed for strengthening were determined via a previously proposed equation predicting the strength. Using these factors, the strengthening of spot-welded lap joints was examined. First, in order to increase the hardened zone, the edge of the nugget was heated with a laser. Next, cross-tension tests were conducted by using spot-welded lap joints that were heated by a laser at various distances from the nugget. It was found that the fracture position and the cross-tension strength (CTS) were governed by whichever was higher: the strength outside HAZ or the strength at the nugget's edge. It was also shown that the cross-tension strength could be improved by 10%.<br>

Journal

Citations (3)*help

See more

References(2)*help

See more

Details

Report a problem

Back to top