The Design of Aluminium Bolted Flange Connections : Part 1 Relationship between Leak Properties and Gasket Loads of Integral Hub Flanges

この論文をさがす

説明

Water leak tests were carried out on aluminium and steel bolted integral hub flange connections of the Japanese Industrial Standards (J.I.S) 10 kgf/cm2 class and a nominal pipe diameter of 150 mm. Bolt loads were measured by strain gauges. Rates of water leakage are detected by a leak detector made of copper wires covered with cotton cloth. The leak detector is very sensitive to leakage and can detect leakage early before a droplet is observed. It is shown that the leak detector output correlates with the calculated gasket load. It is proposed that the highest operating pressure for aluminium flanges be made equal to that of steel flanges of identical dimensions, after confirming that the stress conditions in the flange satisfy the J.I.S. rules.

収録刊行物

  • Bulletin of JSME

    Bulletin of JSME 28 (243), 2181-2187, 1985

    一般社団法人 日本機械学会

詳細情報 詳細情報について