Comments on measurement of the electron cyclotron emission by Fabry-Perot interferometer and the experimental results on ECE in WT-III tokamak.
-
- Dodo Taro
- Department of Physics, Faculty of Science, Ehime University
-
- Sugawa Masao
- Department of Physics, Faculty of Science, Ehime University
Bibliographic Information
- Other Title
-
- Fabry‐Perot干渉計による電子サイクロトロンふく射の測定法とWT‐IIIトカマクにおける実験結果
- Fabry Perot カンショウケイ ニ ヨル デンシ サイクロトロン フク
Search this article
Description
Improvement of the signal to noise ratio of the measurement of electron cyclotron emission (ECE) by scanning Fabry-Perot interferometer is reported. The most important point is the use of the glass beads filter in addition to the capacitive mesh low pass filter. The result of frequency response calibration of the total system is described. The time evolution of the high energy electrons (-100keV) produced in RF current driven tokamak WT-III due to the estimate from the ECE measurement is reported.
Journal
-
- Kakuyūgō kenkyū
-
Kakuyūgō kenkyū 65 (1), 83-109, 1991
The Japan Society of Plasma Science and Nuclear Fusion Research
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001206512452736
-
- NII Article ID
- 130001408399
-
- NII Book ID
- AN00039568
-
- ISSN
- 18849571
- 04512375
-
- NDL BIB ID
- 3701083
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed