Pyroelectric response of poly(vinylidene fluoride) films accompanying minute pressure change.
-
- SASAKI Kazuo
- Department of Physics, Faculty of Science, Hirosaki University
Bibliographic Information
- Other Title
-
- 微小な圧力変化に伴うポリフッ化ビニリデンフィルムの焦電反応
- ビショウ ナ アツリョク ヘンカ ニ トモナウ ポリフッカ ビニリデン フィル
Search this article
Description
A transient change in surface potential was measured for poled poly (vinylidene fluoride) film by applying a small pressure of about 102 Pa in a vacuum vessel under thermal equilibrium condition. The sign of the surface potential corresponds to the polarity of the film. The surface potential change, measured by Kelvin method, was of the order of several hundreds mV, which was much larger than the value expected from the piezoelectric effect under hydrostatic pressure. A definite correlation was recognized between the change in the surface temperature and the surface potential change, which could be interpreted reasonably on the basis of the pyroelectric effect of the film.
Journal
-
- KOBUNSHI RONBUNSHU
-
KOBUNSHI RONBUNSHU 47 (9), 705-708, 1990
The Society of Polymer Science, Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390001206521920000
-
- NII Article ID
- 130003837260
-
- NII Book ID
- AN00085011
-
- ISSN
- 18815685
- 03862186
-
- NDL BIB ID
- 3693426
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed