書誌事項
- タイトル別名
-
- Electropiezodialysis through Cation- and Anion-Exchange Membranes
- ヨウイオン コウカン マク ト インイオン コウカン マク オ トオシテ ノ
この論文をさがす
説明
A three compartment cell was constructed with stainless steel, and the compartments were mutually separated with two ion-exchange membranes. Both the end compartments were connected with a tube filled with an electrolyte solution or two Ag/AgCl electrodes inserted in each end compartment in order to make a closed electric circuit. The electrolyte flux was larger in the case of pair of cation- and anion-exchange membranes than that of a pair of two cation-exchange membranes or two anion-exchange membranes. Moreover, a seven compartment cell was constructed with poly (methyl methacrylate) resin, and the compartments were separated alternately with cation- and anion-exchange membranes. An electropiezodialysis was carried out by applying pressure on the desalting compartments of the seven compartment cell. A part of the electric energy consumption in electrodialysis could be substituted with the energy due to the pressure difference by pressurizing on thedesalting compartments.
収録刊行物
-
- 高分子論文集
-
高分子論文集 41 (6), 331-336, 1984
公益社団法人 高分子学会
- Tweet