Calculation of City Water and Hot Water Consumption by the New Calculation Method (Water Load Calculation)
-
- KOSAKA Shinji
- KOSAKA CONSULTANTS Ltd.
Bibliographic Information
- Other Title
-
- 水負荷計算法による給水・給湯使用量計算
- −ビジネスホテル・シティホテルの給水・給湯使用量−
- -City Water and Hot Water Consumption of City Hotel and Business Hotel-
Search this article
Description
<p>When designing the plumbing system of a building, calculation of its water consumption and hot water consumption is necessary. The data used for that, however, are largely based on historical statistical figures, and there is no consistency between the two figures in many cases. In the water load calculation method, a coefficient of 1.0 is used for the water consumption calculation. The hot water consumption can be calculated by changing the coefficient to 0.75. By applying this method, both the water consumption and the hot water consumption of city hotels and business hotels were calculated. The results of the business hotels were compared with the figures obtained with the water supply fixture unit method, which is used for determining appropriate piping sizes.</p>
Journal
-
- Transactions of the Society of Heating,Air-conditioning and Sanitary Engineers of Japan
-
Transactions of the Society of Heating,Air-conditioning and Sanitary Engineers of Japan 42 (240), 25-33, 2017
The Society of Heating, Air-Conditioning & Sanitary Engineers of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001206545330304
-
- NII Article ID
- 130006434106
-
- ISSN
- 24240486
- 0385275X
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- CiNii Articles
-
- Abstract License Flag
- Disallowed