Evaporative Rate from Skin Surface in Hyperbaric Helium Environment

  • KAKITSUBA Naoshi
    Department of Architecture, School of Science and Technology, Nihon University

Bibliographic Information

Other Title
  • 高圧ヘリウム混合ガス環境における皮膚面からの蒸汗量
  • 高圧ヘリウム混合ガス環境における皮膚面からの蒸汗量〔英文〕
  • コウアツ ヘリウム コンゴウ ガス カンキョウ ニ オケル ヒフメン カラ ノ

Search this article

Abstract

The purpose of this paper is to develop a method to measure quantitatively the rate of evaporative heat loss from the skin surface for the evaluation of thermal conditions in hyperbaric helium environment. The characteristics of a measuring device proposed, Vapor Flow Meter, are tested, and the rate of local skin evaporation of two sedentary subjects are measured by using the proposed device in 4 ATA environment. Based on observed data, the relationship between thermal sensation votes, skin wettedness and mean skin temperature is discussed.