書誌事項
- タイトル別名
-
- Prompt Response to Load Change by Extraction Flow Control
- チュウキセイギョ ニ ヨル フットウスイガタ ゲンシリョク ハツデンショ ノ シュツリョク セイギョホウ ト ソノ オウトウ カイセキ
この論文をさがす
抄録
As nuclear power generation comes to occupy an ever larger portion of electric energy sources, it should become desirable or rather necessary for the nuclear power plants to have prompt load response characteristics to accommodate the necessary spinning reserve of the power system, even if these plants are to be operated in principle as what is known as "base load plants".<BR>The problem treated here is to find the possibility of realizing prompt load response in narrow range of BWR plants, and not wide range automatic power control.<BR>We have analyzed the load response characteristics of BWR plants by means of extraction flow variation. A decrease of the extraction flow was found to cause the plant power to increase through the following three processes:<BR>(1) Steam flow increase in the turbine<BR>(2) Reactivity increase occasioned by reactor pressure rise<BR>(3) Reactivity increase occasioned by reactor feed water temperature drop
収録刊行物
-
- 日本原子力学会誌
-
日本原子力学会誌 11 (9), 532-538, 1969
一般社団法人 日本原子力学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001206550749952
-
- NII論文ID
- 130003746306
-
- NII書誌ID
- AN00188477
-
- ISSN
- 21865256
- 00047120
-
- NDL書誌ID
- 8374826
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可