Long-term Reliability Evaluation of the Diaphragm for Gas Meters
-
- OZAWA Yoshinori
- OSAKA GAS CO., LTD.
-
- YAMAGUCHI Hideki
- OSAKA GAS CO., LTD.
-
- ASADA Akiharu
- OSAKA GAS CO., LTD.
-
- NISHIMURA Hiroyuki
- Kyoto Institute of Technology
Bibliographic Information
- Other Title
-
- ガスメーター用ダイヤフラムの長期信頼性評価
- ガスメーターヨウ ダイヤフラム ノ チョウキ シンライセイ ヒョウカ
Search this article
Abstract
To establish a technique for reproducible instrumental error variation on the plus side of diaphragm gas meters, diaphragms collected from the field were examined so as to determine the major cause of instrumental error variation on the plus side. The authors then carried out tests to reproduce instrumental error variation on the plus side, studying the conditions for a test of accelerated degradation equivalent to 20-year use. As a result, the authors found that the major cause of instrumental error variation on the plus side is diaphragm thermal degradation. The authors also confirmed that the accelerated heat aging conditions that replicate the state of a diaphragm after 20-years' use are 2000 hours at 70°C and 6000 hours at 60°C.
Journal
-
- NIPPON GOMU KYOKAISHI
-
NIPPON GOMU KYOKAISHI 86 (7), 227-233, 2013
THE SOCIRETY OF RUBBER SCIENCE AND TECHNOLOGYY, JAPAN