- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Quality Assurance Procedure for Linear Accelerators Measuring Direct Tissue Maximum Ratio with a Calibration Water Phantom
-
- Harada Takayuki
- Department of Radiology, National Hospital Organization Kanazawa Medical Center Division of Health Sciences, Graduate School of Medical Science, Kanazawa University
-
- Takemura Akihiro
- Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University
Bibliographic Information
- Other Title
-
- 校正用水ファントムを用いたdirect tissue maximum ratio の測定によるリニアックの品質保証
- 臨床技術 校正用水ファントムを用いたdirect tissue maximum ratioの測定によるリニアックの品質保証
- リンショウ ギジュツ コウセイ ヨウスイ ファントム オ モチイタ direct tissue maximum ratio ノ ソクテイ ニ ヨル リニアック ノ ヒンシツ ホショウ
Search this article
Description
<p>In this paper, we proposed an efficient quality assurance method which can measure direct tissue maximum ratio (TMRDir), total scatter factor (Scp, Dir), wedge factor (WFDir), tissue phantom ratio 20/10 (TPR20/10Dir) by using a calibration water phantom and a Farmer chamber. The TMRDir was compared with the calculated TMR (TMRCal) that was calculated from the percentage depth dose at the time of the linear accelerator installation. Scp, Dir, WFDir and TPR20/10Dir calculated from TMRDir were compared with Scp, BD, WFBD, and TPR20/10BD measured at the time of the linear accelerator installation. The difference between TMRDir and TMRCal was approximately within 1% except for using 60° wedge filter. The difference between Scp, Dir and Scp, BD was within 1%, between WFDir and WFBD was within 2%, between TPR20/10Dir and TPR20/10BD was within 1%, these differences were acceptable levels of AAPM TG-142 report. Also, coefficient of variation (CV) of TMRDir, ScpDir, WFDir and TPR20/10Dir when changing days and measuring multiple times were approximately within 1%, these CVs were reference levels of AAPM TG-106 report. We validated that was an efficient quality assurance method by measuring direct tissue maximum ratio, but the propose method has limited in measurable field size.</p>
Journal
-
- Japanese Journal of Radiological Technology
-
Japanese Journal of Radiological Technology 75 (10), 1150-1157, 2019
Japanese Society of Radiological Technology
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001277371336576
-
- NII Article ID
- 130007731556
-
- NII Book ID
- AN00197784
-
- ISSN
- 18814883
- 03694305
-
- NDL BIB ID
- 030067849
-
- PubMed
- 31631108
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- PubMed
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed