Multi-institutional study of a newly developed bioluminescent endotoxin measurement method based on the limulus amebocyte lysate reaction
-
- Kondo Mayumi
- Department of Clinical Engineering, Faculty of Health Sciences, Gunma PAZ University
-
- Uchino Junji
- Mihama Hospital
-
- Murakami Jun
- Department of Clinical Engineering, Tokyo Women’s Medical University
-
- Hoshino Taketoshi
- Department of Clinical Engineering, Meirikai Central General Hospital
-
- Yamashita Yoshihisa
- School of Clinical Engineering, Faculty of Health and Medical Care, Saitama Medical University
-
- Naramura Tomotaka
- Department of Medical Technology, Faculty of Medical Science, University of East Asia
-
- Shibamoto Takashi
- Department of Clinical Engineering, Faculty of Health Sciences, Gunma PAZ University
Bibliographic Information
- Other Title
-
- 新たに開発されたlimulus amebocyte lysate (LAL) 反応を用いた生物発光式エンドトキシン活性値測定装置 (ルミニッツ<sup>®</sup>-ET) の多施設評価
- 新たに開発されたlimulus amebocyte lysate (LAL)反応を用いた生物発光式エンドトキシン活性値測定装置(ルミニッツ-ET)の多施設評価
- アラタ ニ カイハツ サレタ limulus amebocyte lysate (LAL)ハンノウ オ モチイタ セイブツ ハッコウシキ エンドトキシン カッセイチ ソクテイ ソウチ(ルミニッツ-ET)ノ タシセツ ヒョウカ
Search this article
Abstract
<p>Dialysis fluid purification is one way to ensure the safety of dialysis therapy. The level of endotoxins (ET) is an important index for safety management during dialysis because ET exhibit strong and extensive physiological activity. We evaluated the accuracy of a newly developed ET measurement method based on bioluminescence technology, using a common protocol at multiple facilities. In accordance with the validation guidelines prepared by the Japanese Society for Hemodiafiltration, we prepared a common protocol and performed the following evaluations at 6 facilities: the validity of the calibration curve, a blank test, a reaction interfering factor test, and assessments of the assay’s detection limit and the quantitation limit for dialysate measurement. These evaluations indicated that the bioluminescence-based method fulfilled the validation requirements of the HDF Research Group. In conclusion, since it exhibits high sensitivity and allows quick measurements, the new method was confirmed to be useful for biological contamination control of dialysis fluid.</p>
Journal
-
- Nihon Toseki Igakkai Zasshi
-
Nihon Toseki Igakkai Zasshi 51 (10), 591-598, 2018
The Japanese Society for Dialysis Therapy
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001288083610368
-
- NII Article ID
- 40021719628
-
- NII Book ID
- AN10432053
-
- ISSN
- 1883082X
- 13403451
-
- NDL BIB ID
- 029335417
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed