Relationship between Quantitativeness of Iodine and Accuracy of Virtual Non-contrast Image in Dual-energy Computed Tomography
-
- Kayano Shingo
- Department of Radiological Technology, Tohoku University Hospital
-
- Takano Hirokazu
- Department of Radiological Technology, Tohoku University Hospital
-
- Takane Yumi
- Department of Radiological Technology, Tohoku University Hospital
-
- Satomura Ayaka
- Department of Radiological Technology, Tohoku University Hospital
-
- Ono Katsunori
- Department of Radiological Technology, Tohoku University Hospital
-
- Shimura Hirotaka
- Department of Radiological Technology, Tohoku University Hospital
-
- Onodera Shu
- Department of Radiological Technology, Tohoku University Hospital
-
- Sato Kazuhiro
- Health Sciences, Tohoku University Graduate School of Medicine
Bibliographic Information
- Other Title
-
- Dual-energy CT におけるヨードの定量性と仮想単純画像の精度との関係
- 臨床技術 Dual-energy CTにおけるヨードの定量性と仮想単純画像の精度との関係
- リンショウ ギジュツ Dual-energy CT ニ オケル ヨード ノ テイリョウセイ ト カソウ タンジュン ガゾウ ノ セイド ト ノ カンケイ
Search this article
Description
<p>Dual-energy computed tomography (DE-CT) is the promising technology, such as enabling material decomposition, generation of the virtual monochromatic image, and measurement of effective atomic numbers. There are reports that utilization of the virtual non-contrast (VNC) image, the iodine map image, and the virtual monochromatic image can contribute to the improvement of lesion detection and its characterization, compared with conventional contrast CT by single-energy computed tomography (SE-CT). In addition, acquisition of the VNC images makes it possible to skip scanning of true non-contrast CT, which is also expected to reduce exposure. However, a reliable evaluation of the accuracy of the VNC image has not been established, and only a few reports have verified their accuracy. In this study, we evaluated the relationship between the quantitativeness of iodine and the CT value of VNC image. As a result of our study, when the iodine volume was overestimated, the CT value of the VNC image was lower than the reference value, and when the iodine volume was underestimated, the CT value was upper than the reference value. Moreover, we clarified that the CT value of the VNC image greatly diverges as the iodine volume increases.</p>
Journal
-
- Japanese Journal of Radiological Technology
-
Japanese Journal of Radiological Technology 75 (3), 247-253, 2019
Japanese Society of Radiological Technology
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001288129228032
-
- NII Article ID
- 130007617396
-
- NII Book ID
- AN00197784
-
- ISSN
- 18814883
- 03694305
-
- NDL BIB ID
- 029607893
-
- PubMed
- 30890672
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- PubMed
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed