Damping of Frequency Fluctuations of Hybrid Power System by Variable Deloaded Operation of PMSG Based Offshore Wind Farm
-
- Jahan Effat
- Department of Electrical and Electronic Engineering, Kitami Institute of Technology (KIT)
-
- Hazari Md. Rifat
- Department of Electrical and Electronic Engineering, Kitami Institute of Technology (KIT)
-
- Mannan Mohammad Abdul
- Department of Electrical and Electronic Engineering, American International University-Bangladesh (AIUB)
-
- Umemura Atsushi
- Department of Electrical and Electronic Engineering, Kitami Institute of Technology (KIT)
-
- Takahashi Rion
- Department of Electrical and Electronic Engineering, Kitami Institute of Technology (KIT)
-
- Tamura Junji
- Department of Electrical and Electronic Engineering, Kitami Institute of Technology (KIT)
Search this article
Description
<p>This paper focuses on a novel variable deloaded operation of variable speed wind turbines with permanent magnet synchronous generators (VSWT-PMSGs) based offshore wind farm (OWF) to maintain primary reserve, which is connected to onshore grid through voltage source converter based high voltage DC (VSC-HVDC) transmission system. A centralized droop controller with dead band is designed for VSWT-PMSGs to utilize this reserve power to suppress the frequency fluctuations of the onshore grid due to the installations of large-scale fixed speed wind turbines with squirrel cage induction generators (FSWT-SCIGs) based wind farm (WF) and photovoltaic (PV) power station. The combination of variable deloaded operation and centralized droop controller can give better frequency regulation and decrease energy loss due to the deloaded operation. The effectiveness of the proposed variable deloaded operation and centralized droop controller is verified through simulation analyses on a modified IEEE nine-bus test system. The simulation results reveal that the variable deloaded operation can decrease the energy loss compared to the fixed deloaded operation as well as suppress the frequency fluctuations in the same level as the fixed deloaded operation.</p>
Journal
-
- IEEJ Transactions on Power and Energy
-
IEEJ Transactions on Power and Energy 139 (4), 259-268, 2019-04-01
The Institute of Electrical Engineers of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390001288143870848
-
- NII Article ID
- 130007622042
-
- NII Book ID
- AN10136334
-
- ISSN
- 13488147
- 03854213
-
- NDL BIB ID
- 029646493
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
- KAKEN
-
- Abstract License Flag
- Disallowed