- CHOI Byunghyun
- Nuclear Safety Research Center, Japan Atomic Energy Agency
-
- NISHIDA Akemi
- Nuclear Safety Research Center, Japan Atomic Energy Agency
-
- MURAMATSU Ken
- Department of Nuclear Safety Engineering, Tokyo City University
-
- TAKADA Tsuyoshi
- Department of Architecture, The University of Tokyo
書誌事項
- タイトル別名
-
- EVALUATION OF THE EFFECTS OF DIFFERENCES IN BUILDING MODELS ON THE SEISMIC RESPONSE OF A NUCLEAR POWER PLANT STRUCTURE
説明
<p>This study examines two different seismic response analysis models of a nuclear power plant building, including the three-dimensional finite-element (3D FE) model with shell elements and the conventional sway-rocking model. Further, the results obtained using these models are compared for estimating the effects related with the differences between the modeling methods. In addition, the authors analyzed the spatial variations of the response results based on the merits of the 3D FE model, and the potential applications of this information are discussed.</p>
収録刊行物
-
- 日本地震工学会論文集
-
日本地震工学会論文集 20 (2), 2_1-2_16, 2020
公益社団法人 日本地震工学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390002184878153600
-
- NII論文ID
- 130007803305
-
- ISSN
- 18846246
-
- 本文言語コード
- en
-
- 資料種別
- journal article
-
- データソース種別
-
- JaLC
- IRDB
- Crossref
- CiNii Articles
- OpenAIRE
-
- 抄録ライセンスフラグ
- 使用不可