デッドタイムに起因する非線形電力誤差の補償法におけるDual Active Bridgeコンバータの電流実効値低減法

DOI DOI Web Site Web Site Web Site ほか2件をすべて表示 一部だけ表示 被引用文献1件 参考文献13件

書誌事項

タイトル別名
  • Current Reduction Method for Dual Active Bridge Converter in Non-linear Dead-time Compensation Method
  • デッドタイム ニ キイン スル ヒセンケイ デンリョク ゴサ ノ ホショウホウ ニ オケル Dual Active Bridge コンバータ ノ デンリュウ ジッコウチ テイゲンポウ
  • Current reduction method for dual active bridge converter in nonlinear dead‐time compensation method

この論文をさがす

説明

<p>This paper proposes a control method for a dual active bridge (DAB) converter, which achieves both a reduction in the non-linear transmission power error due to the dead-time and a reduction in the inductor current with a three-level operation. The non-linear transmission power error is compensated by designing a zero current period in the inductor current with the three-level operation. In addition, an inductor current reduction method for the three-level operation is also proposed. In the non-linear transmission power error compensation method, the inductor current is reduced by suppressing the circulating current by considering the zero-current period to be the dead-time. The validity of the proposed method is confirmed using a 2.0-kW prototype. The experimental results show that the transmission power error is reduced by up to 85.1%. In addition, the inductor current is reduced by up to 64.1% and the loss is reduced by up to 58.6%. Moreover, the DC offset is eliminated by utilizing the voltage polarity reverse phenomenon in the voltage control.</p>

収録刊行物

被引用文献 (1)*注記

もっと見る

参考文献 (13)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

問題の指摘