Laser-Driven γ -Ray Source for Nondestructive Testing
-
- OISHI Yuji
- Central Research Institute of Electric Power Industry (CRIEPI)
Bibliographic Information
- Other Title
-
- 非破壊検査用レーザー駆動γ線源
- ヒハカイ ケンサヨウ レーザー クドウ γセン ゲン
Search this article
Abstract
Laser-driven γ -ray is expected to be a very useful nondestructive diagnostic tool for large-scale structures because of its potential for high energy, short pulse, high spatial resolution, compactness, and easy control. CRIEPI has proposed a radiographic testing system that consists of a compact laser-driven γ -ray generator and a compact radiographic imaging system. It can be applied to a very narrow space (10 cm) in plant facilities, which are often crowded with pipes and other components. Here we review the recent progress of our research on a laser-driven γ -ray source for nondestructive testing.
Journal
-
- The Review of Laser Engineering
-
The Review of Laser Engineering 42 (1), 32-, 2014
The Laser Society of Japan