Transcatheter Aortic Valve Replacement in Patients With a Small Annulus ― From the Japanese Nationwide Registry (J-TVT) ―
-
- Meguro Kentaro
- Department of Cardiovascular Medicine, Kitasato University
-
- Kumamaru Hiraku
- Department of Healthcare Quality Assessment, Graduate School of Medicine, the University of Tokyo
-
- Kohsaka Shun
- Department of Cardiology, Keio University
-
- Hashimoto Takuya
- Department of Cardiovascular Medicine, Kitasato University
-
- Kakizaki Ryota
- Department of Cardiovascular Medicine, Kitasato University
-
- Kitamura Tadashi
- Department of Cardiovascular Surgery, Kitasato University
-
- Shimizu Hideyuki
- Department of Cardiovascular Surgery, Keio University
-
- Ako Junya
- Department of Cardiovascular Medicine, Kitasato University
この論文をさがす
抄録
<p>Background:The details and consequences of a small aortic annulus among transcatheter aortic valve replacement (TAVR) patients remain uncertain. This study investigated the short-term outcomes in patients with small annular size and compared the 30-day outcome between intra- and supra-annular devices, with similar outer casing diameter in this subgroup.</p><p>Methods and Results:Cases registered in the Japanese national TAVR registry between August 2013 and December 2017 were analyzed. Among a total of 5,870 registered patients, 647 (11.0%) had small annulus (area ≤314 mm2) measured by multi-detector computed tomography. Patients with a small annulus had a significantly smaller indexed effective orifice area (iEOA, 1.10 cm2/m2[0.92–1.35] vs. 1.16 cm2/m2[0.96–1.39], P<0.001) and higher mean pressure gradient (mPG, 10.0 mmHg [6.9–14.2] vs. 8.5 mmHg [6.0–11.5], P<0.001) compared with a normal-sized annulus. Among patients with a small annulus, those receiving a 20 mm intra-annular device had a smaller iEOA (0.94 cm2/m2[0.78–1.06] vs. 1.07 cm2/m2[0.8–1.24], P=0.001) and higher mPG (14.0 mmHg [10.0–18.5] vs. 11.0 [7.0–14.0], P<0.001) compared with those receiving a 23-mm supra-annular device, although the incidence of paravalvular leakage (≥moderate) was similar (14.4% vs. 16.5%, P=0.69).</p><p>Conclusions:Patients with a small annulus were associated with less hemodynamic improvement. A supra-annular device is associated with better echocardiographic improvement in patients with a small annulus, without increasing paravalvular leakage.</p>
収録刊行物
-
- Circulation Journal
-
Circulation Journal advpub (0), 967-976, 2021-02-27
一般社団法人 日本循環器学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390005822568131968
-
- NII論文ID
- 130008056914
-
- NII書誌ID
- AA11591968
-
- ISSN
- 13474820
- 13469843
-
- NDL書誌ID
- 031532160
-
- PubMed
- 33642425
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- PubMed
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可