RSA術後の装具固定は2週間で可能か?
-
- Onishi Shinzo
- Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba
-
- Ogawa Takeshi
- Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba Department of Orthopedic Surgery, Mito Kyodo General Hospital
-
- Noguchi Hiroshi
- Department of Orthopedic Surgery, Mito Red Cross Hospital
-
- Makihara Takeshi
- Department of Orthopedic Surgery, Kasumigaura Medical Center
-
- Ikeda Kazuhiro
- Department of Orthopedic Surgery, Kikkoman General Hospital
-
- Ogawa Kaishi
- Department of Orthopedic Surgery, Showa General Hospital
-
- Watabe Daisuke
- Department of Orthopedic Surgery, Ichihara Hospital
-
- Michinobu Ryuhei
- Department of Orthopedic Surgery, Mito Kyodo General Hospital
-
- Teruya Shotaro
- Department of Orthopedic Surgery, Ibaraki Western Medical Center
-
- Yamazaki Masashi
- Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba
Search this article
Description
RSA術後の装具はADLに支障をきたすため短期間であることが望ましいが,インプラントの緩み,縫合した肩甲下筋腱の断裂が懸念される.術後2週間の装具使用で経過に問題がないか検討した.対象は通常のRSA6肩,BIO-RSA13肩,人工骨頭からRSAへの置換が1肩の計20肩である.術後から他動運動を開始,外旋は30° 以下に制限した.術後1週で外転枕を除去し自動介助運動開始,術後2週でスリング終了,制限なしで自動運動を許可した. 術後脱臼例は無く,画像上5肩にステム周囲lucent lineを認めたが,関節窩側の緩みは全例で認めなかった.自動屈曲可動域の平均は,術前58.0° ,術後1ヶ月69.0° ,2ヶ月97.3° ,3ヶ月113.3° ,6ヶ月133.5° ,1年141.0° であった.エコー検査では肩甲下筋縫合例19肩の2肩に断裂を認め,術前MRIにおいてGoutallier分類III・IVの症例であった.典型的な症例は装具使用2週間で臨床結果に大きな影響はでなかった.
Journal
-
- Katakansetsu
-
Katakansetsu 45 (1), 171-174, 2021
Japan Shoulder Society
- Tweet
Details 詳細情報について
-
- CRID
- 1390007750044496768
-
- NII Article ID
- 130008080450
-
- ISSN
- 18816363
- 09104461
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- CiNii Articles
-
- Abstract License Flag
- Disallowed