軽量コンクリート2種を用いたプレキャストPC床版における高強度スタッドのせん断耐力および疲労強度
書誌事項
- タイトル別名
-
- Shear resistance and fatigue strength of high strength headed stud in precast PC slab using lightweight concrete of class-2
抄録
<p>Recently, the concrete slabs that have been seriously damaged due to aging are being replaced with precast prestressed concrete slabs, in Japan. When replacing the concrete slab of composite girder, it is necessary to reduce the weight of the precast slab in consideration of the effect on the existing steel girder. On the other hand, it is also required to efficiently place studs in the box holes of precast slabs. Therefore, the authors are developing the replacement method in which high strength headed studs are placed on the precast slab using lightweight concrete of class-2. The shear resistance and fatigue strength of high strength headed stud found from the static and fatigue push-out test are reported in this paper.</p>
収録刊行物
-
- 構造工学論文集 A
-
構造工学論文集 A 68A (0), 804-812, 2022
公益社団法人 土木学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390010292831725184
-
- ISSN
- 1881820X
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
-
- 抄録ライセンスフラグ
- 使用不可