A Proposal on Horizontal First Initial Damping Ratio for the Seismic Design of Buildings
-
- Nakamura Naohiro
- Hiroshima University
-
- Satake Naoki
- Structural Quality Assurance Inc.
-
- Ougiya Narumi
- Haseko Corporation
-
- Ito shinji
- Daiwa House Industry
Bibliographic Information
- Other Title
-
- 建築物の耐震設計における水平1次の初期減衰定数の提案
Abstract
<p>The physical properties of the damping of buildings are less elucidated than those of stiffness and mass; however, damping has a significant effect on the behavior of a building against dynamic external forces, such as earthquakes and wind. The damping of buildings comprises two parts, initial damping and hysteresis damping. This paper investigates the ratios of initial damping for ordinary buildings. The proposed damping ratios are 1.5% or less for steel buildings and 2.0% or less for reinforced concrete buildings, and these values are smaller than ratios that are used generally in the current seismic design.</p>
Journal
-
- NCTAM papers, National Congress of Theoretical and Applied Mechanics, Japan
-
NCTAM papers, National Congress of Theoretical and Applied Mechanics, Japan 66 (0), 183-, 2022
National Committee for IUTAM
- Tweet
Details 詳細情報について
-
- CRID
- 1390012313366332032
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
-
- Abstract License Flag
- Disallowed