書誌事項
- タイトル別名
-
- Analysis of Arc Temperature as a Function of Opening Electrodes Timing
この論文をさがす
説明
<p>The gas circuit breakers have the problem of re-ignition after current zero. The instantaneous voltage drop causes enormous damage in the case of current interruption failure. Therefore, it is the responsibility of circuit breaker to interrupt the current quickly and reliably. Efficient cooling of the arc temperature is important in order to prevent the re-ignition caused by the transient recovery voltage. In this paper, the arc temperature as a function of opening electrodes timing was analyzed. As a result, the three-dimensional transition of arc temperature to current zero for each current interruption timing at each sine wave time was obtained. In addition, the opening electrodes timing that decreases the arc conductance at current zero was elucidated.</p>
収録刊行物
-
- 電気学会論文誌. A
-
電気学会論文誌. A 143 (4), 129-135, 2023-04-01
一般社団法人 電気学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390014183322944256
-
- ISSN
- 13475533
- 03854205
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- OpenAIRE
-
- 抄録ライセンスフラグ
- 使用不可