INFLUENCE OF EXCITATION DIRECTION ON FLOATATION OF BURIED PIPES DURING LIQUEFACTION

Bibliographic Information

Other Title
  • 加振方向による液状化時の埋設管浮上り比較実験

Abstract

<p> Previous studies using model tests and analyses have revealed that the floatation of buried pipe was triggered by the buoyancy caused by liquefaction and floatation amount is caused by that the ground around the pipe moves to the bottom of the pipe. Despite advances in numerical analysis technology, there are limited methods to accurately evaluate the soil particles’ moving phenomenon. In addition, most of the existing model tests were conducted with horizontal excitation to the cross section of structure. In this study, horizontal excitation tests were conducted in both the pipe cross section and the pipe axis plane under the same underground conditions, in order to evaluate the effect of excitation direction on the floatation amount of buried pipes. When the pipe was not affected by near-surface sloshing, the floatation amount was 0.5 to 0.87 times smaller when the pipe was excited in the axial direction than when it was excited in the direction of cross section.</p>

Journal

References(5)*help

See more

Details 詳細情報について

Report a problem